D-302756 19
After pressing
OKI
, the PowerMax10-G2 display will read [chime OFF ].
18.
Press the
and buttons to select between "CHIME OFF" and
"melody-chime".
In "melody chime" mode when a chime zone is triggered, chime melody is
heard
or
19.
Press
OKI
to confirm. The PowerMax10-G2 display will read
[DEV SETTINGS].
OKI
You can now press the button to modify the next device of the same type,
or press the
OKI
button to configure the parameters of the device (see the
Accessories Guide for instructions), or press the button to take you to
"
<OK> TO EXIT
".
4.5 Siren Configuration
4.5.1 Configuring the Length of Time the Bell is Allowed to Function
Here you select the length of time the bell (or siren) is allowed to function upon alarm. The bell time starts upon activation
of the siren. Once the bell time expires, the siren is automatically shut down.
Available options are: 1, 3, 4 (default), 8, 10, 15 and 20 minutes.
Note: To comply with EN requirements, the Bell Time should be set to 15 min. max.
To Configure the Length of Time the Bell is Allowed to Function
1. Make sure the system is disarmed and then press the button
repeatedly until the PowerMax10-G2 display reads "INSTALLER MODE".
2.
When the PowerMax10-G2 display reads [INSTALLER MODE], press
OKI
.
The screen will now prompt you to enter your installer code.
OKI
3.
Enter your Installer Code.
CODE
4. Press the or button repeatedly and select the [DEFINE PANEL]
option.
or
5. When the PowerMax10-G2 display reads [DEFINE PANEL], press
OKI
The PowerMax10-G2 display will read [01:ENTRY DELAY 1].
OKI
6.
When the PowerMax10-G2 display reads [01:ENTRY DELAY 1], press
the
or button repeatedly until the display will read [04:BELL TIME].
or
7.
Press
OKI
and make the selection and then press
OKI
to confirm.
The PowerMax10-G2 display will revert to [04:BELL TIME].
OKI
SELECT OPTION
OKI
You can now press the or button to program any other menu in
"
DEFINE PANEL
" or press the button to take you to "
<OK> TO EXIT
".
4.5.2 Enabling the Internal Siren
Here you determine whether the internal siren will sound or remain silent upon alarm (according to the user preference).
Options: piezo siren on (default), piezo siren off.
To Enable the Internal Siren
1. Make sure the system is disarmed and then press the button
repeatedly until the PowerMax10-G2 display reads "INSTALLER MODE".
2.
When the PowerMax10-G2 display reads [INSTALLER MODE], press
OKI
.
elody
hime
hime OFF
4:BELL TIME
01:DEV SETTINGS
EADY 00:00
INSTALLER MODE
ADY 00:00
4:BEL
TIME
1:ENTRY DELAY 1
NTER CODE:
INSTALLER MODE
EFINE PANEL
Komentáře k této Příručce